Ezvent® Continuous Soffit Vent
EXPANSION & CONTRACTION: Siding panels will expand and contract due to changes in temperature. Allow a 1/8"gap between panels and trim.
FASTENERS: Stainless steel fasteners are recommended when installing Tamlyn Xtreme Trim™.
FASTENING: Do not fasten edges of panels until trims are in place. Fasten panel at center and work outward. Fasteners should be staggered on opposite panel edges.
CUTTING: Use a non ferrous carbide miter saw blade when cutting Tamlyn Xtreme Trim™
PAINTING: Use light or pastel paint colors only on Tamlyn PVC or Sherwin-Williams Vinyl Safe™ Paint. Use of dark color paint will cause deformation. Tamlyn vinyl products are not warranted if painted with dark color paint. See Tamlyn PVC Trim Painting Guide
Please follow siding manufacturer's best practice application when installing any Tamlyn accessory. Xtreme Trim™ profiles do not form a moisture management system, the architect and builder are responsible for designing and installing a code compliant building envelope.

Click here to download PDF document
Design Features:
The best looking,
most "framer-friendly", easy to install,
effective continuous soffit vent on the
market. Unique double leg channels hide
edges of soffit material for clean look and
help prevent vent from being pulled up into
subfascia.
- Complies with the International Residential Code requiring that ventilation be balanced 50% exhaust / 50% intake (soffit) in all situations including continuous ridge vents.
- Patents cover use of Tamlyn H Mold at seams.
- 1/8" holes proven to not allow insects/ bugs/bees etc to enter the attic.
| ITEM ID | DEPTH | LENGTH | *NFA |
|---|---|---|---|
| EZV148 | 1/4" | 8 | 9 |
| EZV5168 | 5/16" | 8 | 9 |
| EZV51612 | 5/16" | 12 | 9 |
| EZV7168 | 7/16" | 8 | 9 |
*NFA = net free area / sq.in. per lineal ft.
Material:
Extruded rigid PVC, industry-standard, durable, chemically resistant product designed for outdoor weatherability.